Our websites use cookies on your device to give you the best user experience. By using our websites, you agree to the placement of these cookies. To learn more, read our privacy policy.

Xi CR 22W 0.2-1.05A SDMP 230V C123 sXt

General information

DALI Product ID9892
Product NameXi CR 22W 0.2-1.05A SDMP 230V C123 sXt
Brand NamePhilips
StatusCertified: DALI-2, D4i
Product Part Number9290039747
GTIN8720169343344
Bus unit configuration-

Testing

Test conditions230V, 50Hz, Ambient Temperature 25degC, 22W LED load, ProbitLab2. Driver has Switchable Integrated Bus Power Supply (IBPS). Full testing performed on Main Product. Limited testing is done on both PSU Enable and Disable condition: PSU_Enable tests:101 - 2.1, 4.1; 102 - 2.1, 3.1, 3.4-3.7,3.9,3.11,3.12,3.16,3.17,3.18, 4.5, 4.11, 4.18,4.20, 5.1, 5.5, 6.3,6.17, 6.19, 6.20, 6.21, 6.27, 7.1, 7.2, 7.7, 8.1-8.4; 207 - 7.2.8 PSU_Disable tests: 102_2.1, 3.1 t0 3.18, 4.5, 4.11, 4.18, 5.5,6.17, 6.19, 7.1, 7.2, 7.7, 8.1-8.4
Test typePartial
Family reference product ID9865
DALI test sequence software version2.5.0.0

Technical

Bus current consumption

Maximum current consumed from the bus power supply. If no value shown, 2mA is required.

1.67
Guaranteed supply current

Current that this bus power supply can provide. Total must be sufficient to provide the total "bus current consumption" of all devices.

52
Maximum supply current

Highest current that this bus power supply may provide. Total must not exceed 250mA.

60

Hardware/firmware information

If multiple versions exist then contact the manufacturer for details of the older versions.

Hardware version1.0
Firmware version1.0

Product reference product description

This has 2 family products: 1. Xi CR 40W 0.2-1.05A SDMP 230V C123 sXt 2. Xi CR 22W 0.2-1.05A SDMP 230V C123 sXt

Description

Currently submitted product is the family product of Xi CR 75W 0.2-1.05A SDMP 230V C123 sXt, with the difference in the output power

DALI parts and versions

1012.0
1022.0
2072.0
2502.0
2512.0
2522.0
2532.0

Product properties

LED drivers, ballasts, ECGs, etc.

Maximum current consumed from the bus power supply. If no value shown, 2mA is required.

“Other properties” do not imply certification to such standards.



Reference design of firmware or hardware available