Our websites use cookies on your device to give you the best user experience. By using our websites, you agree to the placement of these cookies. To learn more, read our privacy policy.

DALI-2 certification status

Status of DALI-2 certification

DALI-2 certification (including D4i certification) is based on tests that are created and maintained by the DALI Alliance. DALI-2 tests are derived either from individual Parts of the IEC 62386 standard or from DiiA Specifications.

Allowed Parts for certification

DALI Alliance members that are working towards product certification should use the version (edition/amendment) of each IEC 62386 Part that is listed in the “Allowed Parts of IEC 62386” document (updated February 2024).

Another essential document for product developers is “Clarifications and Recommendations for IEC 62386” which is only available on the member website.

Parts that do not have a green tick against them in the tables below (DALI-2 column) are not yet included in the test sequences. Until released in the test sequences, certification of products that implement such Parts is not possible.

Status by Part number

General requirements

(1) Available for DALI-2 certification

Part Description Published standard DALI-2 (1)
101 System IEC 62386
102 Control gear IEC 62386
103 Control devices IEC 62386
104 Wireless and alternative wired system IEC 62386 DALI+ certification applies
104 Changes & Additions DiiA Specification DALI+ certification applies
105 Firmware update IEC 62386
150 AUX Power Supply IEC 62386

(DiiA Specification withdrawn)

Control gear

(1) Available for DALI-2 certification
(2) Required for D4i certification
(3) DT = Device Type for control gear - more info

Part

Description

Published standard

DALI-2 (1)

D4i (2)

DT (3)

101

General requirements - System

IEC 62386

102

General requirements - Control gear

IEC 62386

201

Fluorescent lamps

IEC 62386

Not planned at present

DT0

202

Self-contained emergency

IEC 62386

DT1

203

HID lamps

IEC 62386

Not planned at present

DT2

204

Low voltage halogen lamps

IEC 62386

Not planned at present

DT3

205

Incandescent lamp dimmer

IEC 62386

DT4

206

Conversion to DC (0/1-10 V)

IEC 62386

DT5

207

LED modules

IEC 62386

DT6

208

Switching

IEC 62386

DT7

209

Colour control

IEC 62386

DT8

220

Centrally-supplied DC emergency operation

IEC 62386

In progress

DT19

224

Integrated light source

IEC 62386

DT23

Part

Description

Published standard

DALI-2 (1)

D4i (2)

DT (3)

250

Integrated Bus Power Supply

IEC 62386

(DiiA Specification withdrawn)

DT49

251

Luminaire Data (Memory Bank 1 Extension)

IEC 62386

(DiiA Specification withdrawn)

DT50

252

Energy Data

IEC 62386

(DiiA Specification withdrawn)

DT51

253

Diagnostics & Maintenance Data

IEC 62386

(DiiA Specification withdrawn)

DT52

254 Additional memory bank for emergency-related parameters DiiA Specification (members only) In progress DT53

150

AUX Power Supply

IEC 62386

(DiiA Specification withdrawn)

Optional

n/a

Control devices

(1) Available for DALI-2 certification
(2) Required for D4i certification

Part

Description

Published standard

DALI-2 (1)

D4i (2)

101

General requirements - System

IEC 62386

103

General requirements - Control devices

IEC 62386

301

Push buttons

IEC 62386

302

Absolute input devices

IEC 62386

303

Occupancy sensors

IEC 62386

304

Light sensors

IEC 62386

305

Colour sensors

IEC 62386

Not yet in progress

306

General-purpose sensors

IEC 62386

Not yet in progress

332

Input control devices - Feedback

IEC 62386

In progress

341

Bluetooth Mesh to DALI Gateway

DiiA Specification

In progress

342

Zigbee to DALI Gateway

DiiA Specification

In progress

351

Luminaire-mounted Control Devices

DiiA Specification